Part Number : SS5614DUS


Standard Recovery Rectifier Dual Die Fault Tolerant Design


DESCRIPTION: 400 VOLT, 0.4 AMP, 2 NS HERMETIC RECTIFIER IN A MELF-1 PACKAGE.


Electrical Characteristics : (All parameters are at Tc = 25°C unless otherwise specified)
RATING SYMBOL MAX UNITS
Peak Inverse Voltage PIV 400 Volts
Maximum Forward Voltage @TA = 25°C Vf 1.2 Volts
Maximum DC Output Current (TC = 100°C) Io 0.4 Amps
Peak Single Cycle Surge Current tp = 8.3 msec IFSM 15 Amps
Maximum Reverse Recovery Time (see datasheet for conditions) Trr 2 nsec
Maximum Reverse Current Irr@PIV @TA = 25°C Irr 0.5 µA
Maximum Reverse Current Irr@PIV @TA = 125°C Irr 25 mA
Maximum Thermal Resistance JC 20 °C/W
Maximum Operating And Storage Temperature Range Top/stg 175 °C

Mechanical Outline: MELF-1

Request Quote

Disclaimer

Datasheets

 5456