Part Number : SAE-5282-12
High Power TVS Module (4kW/ 400ms / 142A) for Lightning Strike Protection in Composite Frame Aircraft
DO-160 Section 22, J1113-11, 142A/ 400ms Compliant
Electrical Characteristics : Tj = 250°C unless otherwise specifiedPARAMETER | SYMBOL | MIN | TYP | MAX | UNIT |
---|---|---|---|---|---|
Peak Pulse Power 50/500 µs waveform | PPPM | - | 4kW/ 400ms | - | KW |
Peak Pulse Current 50/500 µs waveform | IPPM | 142A | - | - | A |
Clamp Voltage @IPPM 50/500 µs waveform | VCL | - | - | 32V | V |
Reverse Standoff Voltage | VRWM | 18V | - | - | V |
Reverse Leakage Current @VRWM | IR | - | - | 250 uA | µA |
Breakdown Voltage | VBR | 25.1V | - | - | V |